1 - To add a KT-MOD-INP16, select the Input
Module tab and then click on Add.
If there is more than one input modules listed, make sure that you select
the correct one before changing the input assignments. Assign names to
the modules in the language fields and choose the options.
2 - Select the DEOL:
Double end-of-line resistor JP4 On checkbox to define a KT-MOD-INP16
module in DEOL.
The entire expansion board is used to provide 8 inputs
with DEOL. These 8 inputs are added of the next group of 8 inputs. For
example, if inputs #33-40 are linked to a DEOL module, inputs #33-40 and
#41-48 will not be available for other modules.
Controller inputs 1-16 are reserved to the inputs on
the KT-400.
3 - Selection of the inputs numbers can be done in two
ways: using the drop-down menu or the Extended selection box. Right-click
on the inputs menu selection to view the Extended selection box, see Using
the Extended Selection Box.
This is an exclusive condition. You cannot select the
same item in the Inputs drop-down menu and in the Elevator inputs drop-down
menu because it will be a duplicate, and the system does not accept any
duplicate. For example, Inputs # 17-24 cannot be selected twice. Another
way to let you understand this concept, is that in the Elevator inputs
menu the same item will not be available for the same door. The same concept
applies for the Elevator outputs menu.